5331-01-433-2683 O-RING Index 5331-01-433-2685 O-RING

National Stock Number:
5910-01-433-2684

Federal Supply Class:
5910

National Item Identification Number:
014332684

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
87106037Z3DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (DRAWINGS)
87106-367037Z3DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (DRAWINGS)
87106-36704222KYOCERA AVX COMPONENTS CORPORATION
87106-3670BMH6MICROSEMI CORP MICRO-CERAMX TECHNOLOGY DIV
87106-3670YBX7UNION TECHNOLOGY CORP.
87106-36729454JOHANSON DIELECTRICS, INC
87106-36758421GREATBATCH SIERRA INC
87106-36767268DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (STANDARD MICROCIRCUIT
87106-36779474GREATBATCH SIERRA INC DBA USE CAGE CODE 58421 FOR CATALOGING


Techincal Specification:
TERMINAL TYPE AND QUANTITY6 UNINSULATED WIRE LEAD
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.500
BODY HEIGHT0.360 INCHES MAXIMUM
BODY LENGTH0.224 INCHES MINIMUM AND 0.275 INCHES MAXIMUM
BODY STYLEDUAL INLINE
BODY WIDTH0.300 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION820.000 MICROFARADS SINGLE SECTION
CASE MATERIALCERAMIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.010 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.250 INCHES NOMINAL
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION200.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP10000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-40.0/+15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
TERMINAL LENGTH0.060 INCHES MINIMUM AND 0.080 INCHES MAXIMUM
TERMINAL SURFACE TREATMENTSOLDER