BODY HEIGHT | 0.150 INCHES NOMINAL |
BODY LENGTH | 0.400 INCHES NOMINAL |
BODY WIDTH | 0.400 INCHES NOMINAL |
BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
CAPACITANCE VALUE PER SECTION | 0.470 MICROFARADS SINGLE SECTION |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.169 INCHES MINIMUM AND 0.231 INCHES MAXIMUM |
CRITICALITY CODE JUSTIFICATION | ZZZY |
MATERIAL | PLASTIC CASE |
NONDERATED OPERATING TEMP | -55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 200.0 DC SINGLE SECTION |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | REFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP. |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO4309 |
TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
TERMINAL LENGTH | 1.250 INCHES MINIMUM |
TERMINAL SURFACE TREATMENT | SOLDER |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TOLERANCE RANGE PER SECTION | -20.00 TO 20.00 PERCENT SINGLE SECTION |
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | -15.0 TO 15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION |