| ELECTRICAL POLARIZATION | POLARIZED |
| ANODE TYPE | SOLID |
| BODY DIAMETER | 0.170 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
| BODY LENGTH | 0.443 INCHES MINIMUM |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| CAPACITANCE VALUE PER SECTION | 3.300 MICROFARADS SINGLE SECTION |
| CASE INSULATION MATERIAL | PLASTIC |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| DC LEAKAGE AT MAXIMUM OPERATING TEMP | 20.0 MICROAMPERES |
| DC LEAKAGE AT REFERENCE TEMP | 1.200 MICROAMPERES |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 4.000 |
| MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-4 |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 75.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
| RELIABILITY INDICATOR | ESTABLISHED |
| SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
| SPECIAL FEATURES | WEIBULL GRADED FAILURE RATE |
| SPECIFICATION/STANDARD DATA | 81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION |
| TERMINAL DIAMETER | 0.018 INCHES MINIMUM AND 0.022 INCHES MAXIMUM |
| TERMINAL LENGTH | 1.250 INCHES MINIMUM AND 1.750 INCHES MAXIMUM |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TEST DATA DOCUMENT | 81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TOLERANCE RANGE PER SECTION | -20.00 TO 20.00 PERCENT SINGLE SECTION |