| BODY HEIGHT | 1.810 INCHES MAXIMUM |
| BODY LENGTH | 2.800 INCHES MAXIMUM |
| BODY STYLE | W/MTG TABS/FLANGES TERMINALS ON OPPOSITE SURFACES |
| BODY WIDTH | 2.780 INCHES MAXIMUM |
| CAPACITANCE VALUE PER SECTION | 20.000 MICROFARADS ALL SECTIONS |
| CASE INSULATION MATERIAL | PLASTIC |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.310 INCHES NOMINAL |
| DIELECTRIC MATERIAL | PLASTIC |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.500 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.190 INCHES MINIMUM AND 2.210 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.190 INCHES MINIMUM AND 2.210 INCHES MAXIMUM |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| INTERNAL ELECTRICAL CONNECTION TYPE | EXTENDED FOIL |
| INSULATION RESISTANCE AT REFERENCE TEMP | 25000.0 MEGOHM-MICROFARADS |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED MOUNTING STUDS |
| NOMINAL THREAD SIZE | 0.164 INCHES |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 200.0 DC ALL SECTIONS |
| NONDERATED OPERATING TEMP | -45.6 CELSIUS MINIMUM AND 71.0 CELSIUS MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| SECTION QUANTITY | 2 |
| TERMINAL LENGTH | 0.600 INCHES MINIMUM AND 0.680 INCHES MAXIMUM |
| TERMINAL DIAMETER | 0.190 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
| TOLERANCE RANGE PER SECTION | -10.00 TO 10.00 PERCENT ALL SECTIONS |