5910-01-116-8353 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-01-116-8355 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-01-116-8354

Federal Supply Class:
5910

National Item Identification Number:
011168354

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
M39006/20-114281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39006/2081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39006/2081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER1.125 INCHES NOMINAL
BODY LENGTH2.435 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE END
CAPACITANCE VALUE PER SECTION14.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER0.535 INCHES NOMINAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP17.0 MICROAMPERES
DC LEAKAGE AT REFERENCE TEMP17.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT16.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS160.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION540.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SPECIFICATION/STANDARD DATA81349-MIL-C-39006/20 GOVERNMENT SPECIFICATION
TERMINAL LENGTH0.406 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG
TEST DATA DOCUMENT81349-MIL-C-39006 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION