| TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
| TERMINAL LENGTH | 1.250 INCHES MINIMUM1.250 INCHES MINIMUM |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| BODY DIAMETER | 0.090 INCHES NOMINAL |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 100.0 DC SINGLE SECTION |
| VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | -15.0/+15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION |
| CASE MATERIAL | PLASTIC |
| TERMINAL SURFACE TREATMENT | SOLDER |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| BODY LENGTH | 0.250 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
| TERMINAL DIAMETER | 0.016 INCHES NOMINAL |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALS |
| CAPACITANCE VALUE PER SECTION | 120.000 PICOFARADS SINGLE SECTION |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.5000 |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |