CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CL55CH122MP381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC3965-2181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY HEIGHT2.000 INCHES NOMINAL
BODY LENGTH1.305 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
BODY WIDTH0.690 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION1200.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
DC LEAKAGE AT MAXIMUM OPERATING TEMP144.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP18.000 MICROAMPERES
FEATURES PROVIDEDHERMETICALLY SEALED CASE
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS2.3
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION30.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
POWER FACTOR AT REFERENCE TEMP IN PERCENT15.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SECTION QUANTITY1
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-3965 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION