5910-00-914-4422 CAPACITOR,FIXED,MICA DIELECTRIC Index 9510-00-914-4429 TRANSFER DIE STEEL

National Stock Number:
5910-00-914-4427

Federal Supply Class:
5910

National Item Identification Number:
009144427

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
0160-01641MY97AGILENT TECHNOLOGIES, INC.
0160-016428480HEWLETT-PACKARD COMPANY
520212-1508638ALLIANT TECHSYSTEMS INC ORDNANCE SYSTEMS DIV
192P3939256289SPRAGUE ELECTRIC CO WORLD HQS
192P39392PTS56289SPRAGUE ELECTRIC CO WORLD HQS
102726-3091417L3HARRIS TECHNOLOGIES, INC.
5G3-014501425LOUIS ALLIS CO THE THIS COMPANY HAS GONE BANKRUPT AND HAS BEEN PURCHASED BY 3 COMPANIES
708D1HP393PK201AX19701NORTH AMERICAN PHILIPS CORP PHILIPS COMPONENTS DISCRETE PRODUCTS DIV
708D1HP393PK201AX80031MEPCO/ELECTRA INC
HEW238M84411AMERICAN SHIZUKI CORP
520212-1594580HONEYWELL INTERNATIONAL INC.


Techincal Specification:
BODY DIAMETER0.290 INCHES NOMINAL
BODY LENGTH0.500 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION39000.000 PICOFARADS SINGLE SECTION
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP50.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP50000.0 MEGOHM-MICROFARADS
INTERNAL ELECTRICAL CONNECTION TYPEEXTENDED FOIL
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION200.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION