2540-00-894-7161 SHAFT ASSEMBLY,FLEXIBLE Index 5910-00-894-7171 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5910-00-894-7163

Federal Supply Class:
5910

National Item Identification Number:
008947163

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
103638-500752L3HARRIS TECHNOLOGIES, INC.
7502006P00794117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
80031-207148UNITED TECHNOLOGIES CORP HAMILTON SUNDSTRAND CORP
SCD80031-207148UNITED TECHNOLOGIES CORP HAMILTON SUNDSTRAND CORP
S104Z93Z5VL63L0R56289SPRAGUE ELECTRIC CO WORLD HQS
80031-273030HAMILTON SUNDSTRAND CORPORATION
TG-P1D56289SPRAGUE ELECTRIC CO WORLD HQS
TGP1056289SPRAGUE ELECTRIC CO WORLD HQS
SCD80031-273030HAMILTON SUNDSTRAND CORPORATION
TGP1080183SPRAGUE PRODUCTS CO


Techincal Specification:
BODY DIAMETER0.675 INCHES MAXIMUM
BODY LENGTH0.156 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, RADIAL TERMINALS
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER0.355 INCHES MINIMUM AND 0.395 INCHES MAXIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.0000
INSULATION RESISTANCE AT REFERENCE TEMP10000.0 MEGOHMS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-10.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT04071-SCD80031-2 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-56.0 TO 22.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION