| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| BODY LENGTH | 1.062 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL DIAMETER | 0.024 INCHES MINIMUM AND 0.028 INCHES MAXIMUM |
| IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS | 743.0 |
| CAPACITANCE VALUE PER SECTION | 3.000 MICROFARADS SINGLE SECTION |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| DC LEAKAGE AT MAXIMUM OPERATING TEMP | 6.0 MILLIAMPERES |
| TOLERANCE RANGE PER SECTION | -20.00/+20.00 PERCENT SINGLE SECTION |
| ELECTRICAL POLARIZATION | NONPOLARIZED |
| BODY DIAMETER | 0.312 INCHES MAXIMUM |
| CASE INSULATION MATERIAL | PLASTIC |
| TERMINAL SURFACE TREATMENT | SOLDER |
| CASE MATERIAL | METAL |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
| TERMINAL LENGTH | 1.500 INCHES NOMINAL |
| DC LEAKAGE AT REFERENCE TEMP | 2.000 MICROAMPERES |
| ANODE TYPE | PLAIN FOIL |