| ELECTRICAL RESISTANCE | 2.15 KILOHMS EACH RESISTOR |
| AMBIENT TEMP AT FULL RATED POWER | 125.0 CELSIUS |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
| BODY DIAMETER | 0.75 INCHES NOMINAL |
| BODY LENGTH | 0.25 INCHES NOMINAL |
| INCLOSURE TYPE | ENCAPSULATED |
| MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | C |
| POWER DISSIPATION RATING IN WATTS | 0.5 FREE AIR |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.01 |
| RELIABILITY INDICATOR | ESTABLISHED |
| RESISTANCE TOLERANCE IN PERCENT | -1.0 TO 1.0 EACH RESISTOR |
| STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 175.0 TEMP RANGE OF FIRST TEMP COEFFICIENT |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0 TO 100.0 FIRST TEMP COEFFICIENT |
| TERMINAL TYPE | WIRE LEAD |