| ELECTRICAL RESISTANCE | 1.000 KILOHMS |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
| BODY HEIGHT | 0.119 INCHES MINIMUM AND 0.129 INCHES MAXIMUM |
| BODY LENGTH | 0.245 INCHES MINIMUM AND 0.268 INCHES MAXIMUM |
| BODY WIDTH | 0.015 INCHES MINIMUM AND 0.033 INCHES MAXIMUM |
| CRITICALITY CODE JUSTIFICATION | AGAV |
| INCLOSURE METHOD | UNINCLOSED |
| POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
| RELIABILITY INDICATOR | ESTABLISHED |
| RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-55342/2 GOVERNMENT SPECIFICATION |
| STYLE DESIGNATOR | TERMINATION PAD EACH END |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0 TO 150.0 |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0 TO 100.0 |
| TERMINAL TYPE | TERMINAL TYPE PER BODY STYLE |