| ELECTRICAL RESISTANCE | 294.000 KILOHMS |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
| BODY HEIGHT | 0.010 INCHES MINIMUM AND 0.040 INCHES MAXIMUM |
| BODY LENGTH | 0.045 INCHES MINIMUM AND 0.060 INCHES MAXIMUM |
| BODY WIDTH | 0.070 INCHES MINIMUM AND 0.080 INCHES MAXIMUM |
| INCLOSURE METHOD | UNINCLOSED |
| POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
| RELIABILITY INDICATOR | ESTABLISHED |
| RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-55342/6 GOVERNMENT SPECIFICATION |
| STYLE DESIGNATOR | TERMINATION PAD EACH END |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0 TO 100.0 |
| TERMINAL TYPE | TERMINAL TYPE PER BODY STYLE |
| TEST DATA DOCUMENT | 81349-MIL-R-55342 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |