| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0/+7.0 4TH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0/+9.0 2ND RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0/+9.0 5TH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/+12.0 6TH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0/+15.0 1ST RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0/+15.0 7TH RESISTANCE-TEMPERATURE POINT |
| SPECIFICATION/STANDARD DATA | 81349-MIL-T-23648/19 GOVERNMENT SPECIFICATION |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 30.75 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 39.5 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 43.15 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 58.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 67.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 77.25 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 87.5 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.55 |
| STYLE DESIGNATOR | ROD |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUM |
| TERMINAL LENGTH | 1.200 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| TEST DATA DOCUMENT | 81349-MIL-T-23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| THERMAL TIME CONSTANT IN SECONDS | 60.0 |
| AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
| BODY LENGTH | 0.270 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.090 INCHES MINIMUM AND 0.110 INCHES MAXIMUM |
| III ZERO POWER RESISTANCE | 50.000 OHMS |
| INCLOSURE TYPE | ENCAPSULATED |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.5 |
| MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 0.25 WATTS |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0/+7.0 3RD RESISTANCE-TEMPERATURE POINT |