| ELECTRICAL RESISTANCE | 100.000 KILOHMS FIRST INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 300.000 KILOHMS THIRD INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 150.000 KILOHMS SECOND INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 450.000 KILOHMS HIGHEST RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 50.000 KILOHMS LOWEST RESISTANCE VALUE |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 125.0 |
| BODY HEIGHT | 0.062 INCHES NOMINAL |
| BODY LENGTH | 0.600 INCHES NOMINAL |
| BODY WIDTH | 0.250 INCHES NOMINAL |
| CUBIC MEASURE | 0.009 CUBIC INCHES |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 HIGHEST RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 SECOND INTERMEDIATE RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 FIRST INTERMEDIATE RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 THIRD INTERMEDIATE RESISTANCE VALUE |
| INCLOSURE METHOD | ENCAPSULATED |
| POWER DISSIPATION RATING IN WATTS | 0.022 TOTAL NETWORK LOCATION NOT OTHERWISE SPECIFIED |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 EACH RESISTOR |
| STYLE DESIGNATOR | SINGLE INLINE |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 LOCATION NOT OTHERWISE SPECIFIED |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -150.0 TO 150.0 LOCATION NOT OTHERWISE SPECIFIED |
| TERMINAL LENGTH | 0.125 INCHES NOMINAL |
| TERMINAL QUANTITY | 6 |
| TERMINAL TYPE | PIN |