| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| BODY LENGTH | 0.270 INCHES MAXIMUM |
| CUBIC MEASURE | 0.704 CUBIC INCHES |
| INCLOSURE TYPE | ENCAPSULATED |
| OVERALL LENGTH | 11.260 INCHES MINIMUM AND 13.260 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 0.014 WATTS |
| MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER | 0.138 INCHES |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING THREAD QUANTITY | 32 PER INCH |
| OVERALL DIAMETER | 0.260 INCHES MAXIMUM |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.8 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.5 TO 12.5 FOURTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.5 TO 12.5 FIFTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.5 TO 14.5 SIXTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 THIRD RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.3 TO 16.3 SEVENTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.8 TO 17.8 EIGHTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -19.2 TO 19.2 NINTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -19.3 TO 19.3 SECOND RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.1 TO 20.1 FIRST RESISTANCE-TEMPERATURE POINT |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| STYLE DESIGNATOR | SCREW MOUNTED |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -20.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TERMINAL LENGTH | 11.000 INCHES MINIMUM AND 13.000 INCHES MAXIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 75.0 |
| THREAD LENGTH | 0.160 INCHES MINIMUM AND 0.180 INCHES MAXIMUM |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 28.5 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 294.0 OHMS NINTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.9 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 74.3 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 924.0 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 10.000 KILOHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -3.90 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.0 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 401.0 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 504.0 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 549.2 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |