| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| BODY LENGTH | 0.300 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.105 INCHES MAXIMUM |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 0.125 WATTS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 30.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 18.759 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 55.77 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 65.13 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 74.1 KILOHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 39.000 KILOHMS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 27.768 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 31.746 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 47.190 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | ROD |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TERMINAL LENGTH | 1.370 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| TEST DATA DOCUMENT | 80063-A3013016 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| THERMAL TIME CONSTANT IN SECONDS | 20.0 |