| AMBIENT TEMP AT FULL RATED POWER | 100.0 CELSIUS |
| BODY LENGTH | 0.150 INCHES NOMINAL |
| BODY OUTSIDE DIAMETER | 0.070 INCHES NOMINAL |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 125.00 MILLIWATTS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.5 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 SIXTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 FIRST RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 SEVENTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0 TO 7.0 THIRD RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0 TO 7.0 FOURTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 SECOND RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.1 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.3 KILOHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 503.2 OHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 567.8 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 816.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 374.0 OHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 965.6 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| ZERO POWER RESISTANCE | 680.000 OHMS |
| STYLE DESIGNATOR | ROD |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TERMINAL LENGTH | 1.250 INCHES NOMINAL |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| TEST DATA DOCUMENT | 80249-730650 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| THERMAL TIME CONSTANT IN SECONDS | 60.0 |