5330-01-104-8539 SEAL RING,METAL Index 5935-01-104-8541 BACKSHELL,ELECTRICAL CONNECTOR

National Stock Number:
5905-01-104-8540

Federal Supply Class:
5905

National Item Identification Number:
011048540

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
958043-1C82577RAYTHEON COMPANY
UUA41J815801HONEYWELL INTERNATIONAL INC.


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY OUTSIDE DIAMETER0.095 INCHES MAXIMUM
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS1.0
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-1.0 TO 1.0 ALL RESISTANCE-TEMPERATURE POINTS
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.0 MEGOHMS FIRST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP185.9 OHMS FOURTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP678.3 OHMS THIRD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-1.0 TO 1.0
ZERO POWER RESISTANCE10.000 KILOHMS
ZERO POWER RESISTANCE AT SPECIFIED TEMP3.6 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORBEAD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.008 INCHES NOMINAL
TERMINAL LENGTH2.875 INCHES MINIMUM AND 3.125 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
TEST DATA DOCUMENT82577-958043 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
THERMAL TIME CONSTANT IN SECONDS10.0