5905-01-101-3894 RESISTOR,FIXED,WIRE WOUND,INDUCT Index 5905-01-101-3897 RESISTOR,FIXED,WIRE WOUND,INDUCT

National Stock Number:
5905-01-101-3895

Federal Supply Class:
5905

National Item Identification Number:
011013895

Description:
RESISTOR,FIXED,WIRE WOUND,INDUCT

Detail:
INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.


Manufacturer Information:
0811-12041LQK8KEYSIGHT TECHNOLOGIES, INC.
0811-120428480HEWLETT-PACKARD COMPANY
561A834ZE2001526GENICOM CORP
16763248-08028009SYPRIS ELECTRONICS, LLC
0813-120428480HEWLETT-PACKARD COMPANY
12-712065-2352414EMERSON ELECTRIC CO COMPUTER POWER DIV
KM500-2000J19587KELVIN INDUSTRIES INC
MIL-PRF-39007/681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39007/681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILR39007-681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR74S2000FP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR74S2000FR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RS5-2000HMP0RM391637VISHAY DALE ELECTRONICS, LLC
RS5X012B200R0J91637VISHAY DALE ELECTRONICS, LLC
SS5W2000HMSP0RM3PCT00213STRUTHERS-DUNN INC.
T2000J54294SHALLCROSS INC
RWR74S2000FS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL RESISTANCE200.000 OHMS
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER275.0
BODY DIAMETER0.312 INCHES NOMINAL
BODY LENGTH0.875 INCHES NOMINAL
CUBIC MEASURE0.067 CUBIC INCHES
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION RATING IN WATTS5.000 FREE AIR
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
RELIABILITY INDICATORESTABLISHED
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
SPECIFICATION/STANDARD DATA81349-MIL-R-39007/6 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 275.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-20.0 TO 20.0
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
UNPACKAGED UNIT WEIGHT5.000 GRAMS