5905-01-101-1123 RESISTOR,NETWORK Index 5905-01-101-1125 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5905-01-101-1124

Federal Supply Class:
5905

National Item Identification Number:
011011124

Description:
RESISTOR NETWORK,FIXED,FILM

Detail:
An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.


Manufacturer Information:
4710003-00129436CYBERGUARD CORPORATION


Techincal Specification:
ELECTRICAL RESISTANCE320.000 OHMS EACH RESISTOR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER70.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER125.0
BODY HEIGHT0.350 INCHES MAXIMUM
BODY LENGTH0.660 INCHES NOMINAL
BODY WIDTH0.100 INCHES MAXIMUM
CUBIC MEASURE0.023 CUBIC INCHES
IDENTICAL VALUE RESISTOR QUANTITY4 EACH RESISTOR
INCLOSURE METHODENCAPSULATED
POWER DISSIPATION RATING IN WATTS1.000 TOTAL NETWORK LOCATION NOT OTHERWISE SPECIFIED
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE IN PERCENT-5.000 TO 5.000 EACH RESISTOR
SCHEMATIC DIAGRAM DESIGNATORLADDER NETWORK
STYLE DESIGNATORSINGLE INLINE
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 145.0 LOCATION NOT OTHERWISE SPECIFIED
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-200.0 TO 200.0 LOCATION NOT OTHERWISE SPECIFIED
TERMINAL LENGTH0.120 INCHES MINIMUM AND 0.140 INCHES MAXIMUM
TERMINAL QUANTITY6
TERMINAL TYPEPIN