| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| BODY LENGTH | 0.285 INCHES NOMINAL |
| BODY OUTSIDE DIAMETER | 0.100 INCHES NOMINAL |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 2.50 MILLIWATTS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.2 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 546.3 OHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 727.7 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| ZERO POWER RESISTANCE | 470.000 OHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.55 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 289.6 OHMS FIRST RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | ROD |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TERMINAL LENGTH | 1.200 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| TEST DATA DOCUMENT | 81349-MIL-T-23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| THERMAL TIME CONSTANT IN SECONDS | 60.0 |