ZERO POWER RESISTANCE | 55.330 KILOHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -1.0 TO 1.0 |
INCLOSURE TYPE | ENCASED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | PROBE |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 95.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| 110.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 678.3 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 3.759 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -1.0 TO 1.0 ALL RESISTANCE-TEMPERATURE POINTS |
BODY LENGTH | 0.264 INCHES NOMINAL |
PROBE LENGTH | 12.000 INCHES NOMINAL |
PROBE DIAMETER | 0.012 INCHES NOMINAL |
WIDTH ACROSS FLATS | 0.250 INCHES NOMINAL |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER | 0.164 INCHES |
MOUNTING THREAD QUANTITY | 32 PER INCH |
THREAD LENGTH | 0.125 INCHES NOMINAL |