| ELECTRICAL RESISTANCE | 17.320 KILOHMS FIRST INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 20.000 KILOHMS SECOND INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 20.953 KILOHMS THIRD INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 23.072 KILOHMS FOURTH INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 30.000 KILOHMS FIFTH INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 30.115 KILOHMS SIXTH INTERMEDIATE RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 52.795 KILOHMS HIGHEST RESISTANCE VALUE |
| ELECTRICAL RESISTANCE | 7.507 KILOHMS LOWEST RESISTANCE VALUE |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
| BODY HEIGHT | 0.100 INCHES MAXIMUM |
| BODY LENGTH | 0.390 INCHES NOMINAL |
| BODY WIDTH | 0.395 INCHES MAXIMUM |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 HIGHEST RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 SIXTH INTERMEDIATE RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 THIRD INTERMEDIATE RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 2 FOURTH INTERMEDIATE RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 2 FIFTH INTERMEDIATE RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 2 FIRST INTERMEDIATE RESISTANCE VALUE |
| IDENTICAL VALUE RESISTOR QUANTITY | 2 SECOND INTERMEDIATE RESISTANCE VALUE |
| POWER DISSIPATION RATING IN WATTS | 0.100 TOTAL NETWORK LOCATION NOT OTHERWISE SPECIFIED |
| SCHEMATIC DIAGRAM DESIGNATOR | SERIES NETWORK |
| STYLE DESIGNATOR | FLAT PACK |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 LOCATION NOT OTHERWISE SPECIFIED |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 150.0 LOCATION NOT OTHERWISE SPECIFIED |
| TERMINAL QUANTITY | 14 |
| TERMINAL TYPE | WIRE LEAD |
| TEST DATA DOCUMENT | 06481-912162 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |