| AMBIENT TEMP AT FULL RATED POWER | 100.0 CELSIUS |
| BODY LENGTH | 0.391 INCHES MINIMUM AND 0.421 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 250.00 MILLIWATTS |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.3 TO 0.3 SECOND RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -3.3 TO 3.3 FIRST RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.1 TO 5.1 THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 158.4 OHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 277.2 OHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 696.3 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| ZERO POWER RESISTANCE | 330.000 OHMS |
| STYLE DESIGNATOR | ROD |
| SURFACE TREATMENT | TIN TERMINAL |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -75.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| TERMINAL LENGTH | 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 34.8 |