5920-00-988-2040 FUSE,CARTRIDGE Index 5905-00-988-2054 RESISTOR,FIXED,FILM

National Stock Number:
5905-00-988-2042

Federal Supply Class:
5905

National Item Identification Number:
009882042

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
1861488869EATON CORP ELECTRONIC INSTRUMENTATION DIV LOS ANGELES PLANT
28D131L9U5MEASUREMENT SPECIALTIES, INC.
28D1383186MEAS US LLC DIV TEMPERATURE PRODUCTS GROUP DBA MEASUREMENT SPECIALTIES


Techincal Specification:
BODY OUTSIDE DIAMETER0.200 INCHES NOMINAL0.200 INCHES NOMINAL
BODY WIDTH0.029 INCHES NOMINAL0.029 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS7.07.0
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHEDNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 SECOND RESISTANCE-TEMPERATURE POINT-10.0 TO 10.0 SECOND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 SEVENTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 EIGHTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 EIGHTH RESISTANCE-TEMPERATURE POINT-7.0 TO 7.0 THIRD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 FIRST RESISTANCE-TEMPERATURE POINT-10.0 TO 10.0 FIRST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.0 TO 5.0 FOURTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.0 TO 5.0 FIFTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-7.0 TO 7.0 SIXTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP119.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT119.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP12.8 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT12.8 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP120.0 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT120.0 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP13.5 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT13.5 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP2.3 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT2.3 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP25.5 OHMS SIXTH RESISTANCE-TEMPERATURE POINT25.5 OHMS SIXTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP270.0 OHMS THIRD RESISTANCE-TEMPERATURE POINT270.0 OHMS THIRD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE750.000 OHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-4.40-4.40
ZERO POWER RESISTANCE AT SPECIFIED TEMP51.0 OHMS FIFTH RESISTANCE-TEMPERATURE POINT51.0 OHMS FIFTH RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORDISK
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER125.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT125.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT150.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER300.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT300.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER75.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT75.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-60.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT-60.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT100.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.020 INCHES NOMINAL0.020 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES NOMINAL1.250 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS13.013.0