5930-00-978-4072 ADAPTER,SWITCH ACTUATOR Index 5950-00-978-4079 COIL,RADIO FREQUENCY

National Stock Number:
5905-00-978-4078

Federal Supply Class:
5905

National Item Identification Number:
009784078

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
143-201FAG-A0102606BAXTER HEALTHCARE CORPORATION DBA BAXTER BIOTECH DIV TRANSFUSION THERAPIES
402136-112909CARDION INC
KB22J102606BAXTER HEALTHCARE CORPORATION DBA BAXTER BIOTECH DIV TRANSFUSION THERAPIES
6740-160024655GENRAD INC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS25.0 CELSIUS
BODY OUTSIDE DIAMETER0.200 INCHES NOMINAL0.200 INCHES NOMINAL
BODY WIDTH0.055 INCHES NOMINAL0.055 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS5.05.0
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHEDNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-11.9 TO 11.9 TENTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.1 TO 12.1 NINTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.3 TO 12.3 EIGHTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.7 TO 12.7 SEVENTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.2 TO 13.2 SIXTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.8 TO 13.8 FIFTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.5 TO 14.5 FOURTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.1 TO 15.1 THIRD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.8 TO 15.8 SECOND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.1 TO 16.1 FIRST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.4879 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT1.4879 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP11.916 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT11.916 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP165.52 OHMS FIFTH RESISTANCE-TEMPERATURE POINT165.52 OHMS FIFTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP565.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT565.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP58.98 OHMS SIXTH RESISTANCE-TEMPERATURE POINT58.98 OHMS SIXTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP6.31 OHMS TENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP8.424 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT8.424 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP9.544 OHMS NINTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE200.000 OHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-3.90-3.90
ZERO POWER RESISTANCE AT SPECIFIED TEMP24.9 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT24.9 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP4.532 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT4.532 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORDISK
SURFACE TREATMENTSOLDER TERMINAL
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-20.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT-20.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-40.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT-40.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-50.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT-50.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT0.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER120.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT120.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER130.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT130.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT150.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER30.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT30.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER60.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT60.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER90.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT90.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.020 INCHES NOMINAL0.020 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS18.018.0