ZERO POWER RESISTANCE | 10.120 OHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
INCLOSURE TYPE | ENCAPSULATED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | ROD |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
MAXIMUM POWER DISSIPATION RATING | 0.50 WATTS |
AMBIENT TEMP AT FULL RATED POWER | 125.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 200.0 DEG CELSIUS |
THERMAL TIME CONSTANT IN SECONDS | 80.0 |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 7.5 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| 80.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| 100.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 316.8 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 124.8 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 72.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
BODY LENGTH | 0.906 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 0.219 INCHES NOMINAL |
TERMINAL LENGTH | 1.375 INCHES NOMINAL |
TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
REFERENCE TEMP IN DEG CELSIUS | 25.0 |
MAXIMUM CURRENT RATING | 25.00 AMPERES |