| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| BODY LENGTH | 0.625 INCHES NOMINAL |
| BODY OUTSIDE DIAMETER | 0.219 INCHES NOMINAL |
| CUBIC MEASURE | 0.018 CUBIC INCHES |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 11.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.6 TO 10.6 FOURTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.3 TO 12.3 FIFTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.9 TO 12.9 THIRD RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.1 TO 14.1 SIXTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.3 TO 14.3 SECOND RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.2 TO 16.2 SEVENTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.6 TO 16.6 FIRST RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.9 TO 17.9 EIGHTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -19.3 TO 19.3 NINTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.8 TO 20.8 TENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 12.5 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 19.5 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.3 KILOHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.3 KILOHMS TENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.5 KILOHMS NINTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.8 KILOHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 8.0 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 5.000 KILOHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.90 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.0 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.0 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.5 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | ROD |
| SURFACE TREATMENT | SOLDER TERMINAL |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 120.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 140.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 20.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 40.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -20.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TERMINAL LENGTH | 1.380 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 25.0 |