| AMBIENT TEMP AT FULL RATED POWER | 125.0 CELSIUS |
| BODY LENGTH | 0.906 INCHES NOMINAL |
| BODY OUTSIDE DIAMETER | 0.219 INCHES NOMINAL |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM CURRENT RATING | 25.00 AMPERES |
| MAXIMUM OPERATING TEMP | 200.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 2.25 WATTS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.5 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| STYLE DESIGNATOR | ROD |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 16.1 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.6 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 68.6 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 4.600 KILOHMS |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -17.8 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -51.1 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 18.3 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 54.4 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 93.3 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TERMINAL LENGTH | 1.375 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 60.0 |