| BODY HEIGHT | 0.080 INCHES NOMINAL |
| BODY LENGTH | 0.080 INCHES NOMINAL |
| BODY WIDTH | 0.060 INCHES NOMINAL |
| INCLOSURE TYPE | ENCAPSULATED |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 1.4 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| STYLE DESIGNATOR | WAFER |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.006 INCHES NOMINAL |
| TERMINAL LENGTH | 2.000 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 3.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 12.5 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 100.000 KILOHMS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 53.2 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.8 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |