National Stock Number: 5905-00-752-4048
Federal Supply Class: 5905
National Item Identification Number: 007524048
Description: RESISTOR,THERMAL
Detail: A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
|
Manufacturer Information:
| 51CA8 | 90634 | GULTON INDUSTRIES INC | | 51CA8 | 99564 | AMETEK, INC. |
|
Techincal Specification:
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -15.0 TO 15.0 | | ZERO POWER RESISTANCE | 100.000 KILOHMS | | STYLE DESIGNATOR | ROD | | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT | | BODY LENGTH | 0.500 INCHES NOMINAL | | BODY OUTSIDE DIAMETER | 0.188 INCHES NOMINAL | | CUBIC MEASURE | 0.014 CUBIC INCHES | | INCLOSURE TYPE | ENCAPSULATED | | REFERENCE TEMP IN DEG CELSIUS | 25.0 | | RELIABILITY INDICATOR | NOT ESTABLISHED | | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS | | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 11.4 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT | | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 20.0 MEGOHMS FIRST RESISTANCE-TEMPERATURE POINT | | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -60.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT | | TERMINAL LENGTH | 1.500 INCHES MINIMUM | | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
|
|