| AMBIENT TEMP AT FULL RATED POWER | 75.0 CELSIUS |
| BODY OUTSIDE DIAMETER | 0.400 INCHES NOMINAL |
| BODY WIDTH | 0.150 INCHES MAXIMUM |
| CUBIC MEASURE | 0.008 CUBIC CENTIMETERS |
| INCLOSURE TYPE | UNINCLOSED |
| MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 200.00 MILLIWATTS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 8.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 20.0 OHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 240.0 OHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 32.400 OHMS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.3 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | DISK |
| SURFACE TREATMENT | TIN TERMINAL |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 147.0 FAHRENHEIT THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 6.7 FAHRENHEIT FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 99.5 FAHRENHEIT SECOND RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TERMINAL LENGTH | 2.000 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 80.0 |