| EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 354.0 NOMINAL |
| ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS ALL SECTIONS |
| ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION |
| ACTUATOR TYPE | SINGLE SHAFT |
| AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 40.0 ALL SECTIONS |
| AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 80.0 ALL SECTIONS |
| BODY DIAMETER | 1.780 INCHES MAXIMUM |
| BODY LENGTH | 2.750 INCHES MAXIMUM |
| BODY STYLE | CYLINDRICAL SERVO MOUNTED |
| FIXED TAP QUANTITY PER SECTION | 1 1ST SECTION AND 2 2ND SECTION AND 2 4TH SECTION |
| FUNCTION CHARACTERISTIC PER SECTION | ALL SECTIONS LINEAR |
| FUNCTION CONFORMITY PER SECTION | ALL SECTIONS TERMINAL BASE LINEARITY |
| FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.00 TO 1.00 ALL SECTIONS |
| LATERAL RUNOUT | 0.0025 INCHES |
| MAXIMUM RUNNING TORQUE | 0.80 INCH-OUNCES |
| MAXIMUM STARTING TORQUE | 1.60 INCH-OUNCES |
| MOUNTING LIP DEPTH | 0.0930 INCHES NOMINAL |
| MOUNTING LIP DIAMETER | 1.7800 INCHES MAXIMUM |
| MOUNTING METHOD | CLAMP RING |
| PILOT DIAMETER | 1.5520 INCHES MINIMUM AND 1.5620 INCHES MAXIMUM |
| PILOT LENGTH | 0.0620 INCHES NOMINAL |
| PILOT DIAMETER RUNOUT | 0.00100 INCHES |
| POWER DISSIPATION RATING PER SECTION IN WATTS | 2.5 FREE AIR ALL SECTIONS |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 ALL SECTIONS |
| ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
| SECTION QUANTITY | 4 |
| SHAFT DIAMETER | 0.2495 INCHES MINIMUM AND 0.2500 INCHES MAXIMUM |
| SHAFT LENGTH | 0.625 INCHES NOMINAL |
| SHAFT RADIAL PLAY | 0.0015 INCHES |
| SHAFT RUNOUT | 0.0005 INCHES |
| SHAFT END PLAY | 0.00500 INCHES |
| SHAFT STYLE | ROUND, SLOTTED |
| TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 277.0 1ST SECTION AND 9.0 2ND SECTION AND 268.0 1ST SECTION AND 9.0 4TH SECTION AND 268.0 4TH SECTION |
| TAP LOCATION TOLERANCE PER SECTION | -1.0 TO 1.0 DEG ANGULAR ROTATION ALL SECTIONS |
| TEMP COEFFICIENT OF RESISTANCE WIRE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO 20.0 ALL SECTIONS |
| TERMINAL LOCATION | LONGITUDINALLY POSITIONED ON THE CIRCUMFERENCE |
| TERMINAL TYPE AND QUANTITY | 17 TURRET |
| UNDERCUT DIAMETER | 1.562 INCHES MAXIMUM |
| UNDERCUT WIDTH | 0.0730 INCHES MINIMUM |