5950-00-472-0885 COIL,RADIO FREQUENCY Index 5905-00-472-0896 RESISTOR,THERMAL

National Stock Number:
5905-00-472-0892

Federal Supply Class:
5905

National Item Identification Number:
004720892

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
992432-111447L3 TECHNOLOGIES, INC.
992432-149671LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER37.8 CELSIUS37.8 CELSIUS
BODY OUTSIDE DIAMETER0.270 INCHES MAXIMUM
BODY WIDTH0.225 INCHES MAXIMUM0.225 INCHES MAXIMUM
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS150.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING880.00 MILLIWATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS7.07.0
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHEDNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.8 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP7.1 OHMS FIFTH RESISTANCE-TEMPERATURE POINT7.1 OHMS FIFTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP19.9 OHMS FOURTH RESISTANCE-TEMPERATURE POINT19.9 OHMS FOURTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP232.5 OHMS SECOND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP95.4 OHMS THIRD RESISTANCE-TEMPERATURE POINT95.4 OHMS THIRD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE145.000 OHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS7.307.30
STYLE DESIGNATORDISK
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-21.5 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER104.4 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER25.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.020 INCHES NOMINAL0.020 INCHES NOMINAL
TERMINAL LENGTH0.065 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS25.0


Click here to Register for Free 30-day Trial