| BODY LENGTH | 0.375 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.220 INCHES MAXIMUM |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 8.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 18.0 OHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.3 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 0.1 OHMS TENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 0.2 OHMS NINTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 0.4 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 0.5 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 0.7 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.6 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 1.000 KILOHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -3.10 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.2 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.6 OHMS SECOND RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | ROD |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 37.8 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -10.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -20.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -45.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 10.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TERMINAL LENGTH | 1.125 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 22.0 |