| EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 3528.0 NOMINAL |
| ELECTRICAL RESISTANCE PER SECTION | 50.0 KILOHMS 1ST SECTION AND 100.0 KILOHMS 2ND SECTION |
| ACTUATOR TYPE | SINGLE SHAFT |
| ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
| AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 ALL SECTIONS |
| AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 ALL SECTIONS |
| BODY DIAMETER | 0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM |
| BODY LENGTH | 1.775 INCHES MAXIMUM |
| BODY STYLE | CYLINDRICAL SERVO MOUNTED |
| FIXED TAP QUANTITY PER SECTION | 5 2ND SECTION |
| FUNCTION CHARACTERISTIC PER SECTION | 1ST SECTION TABLE AND 2ND SECTION LINEAR |
| FUNCTION CONFORMITY PER SECTION | 2ND SECTION INDEPENDENT LINEARITY |
| FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.075 TO 0.075 2ND SECTION |
| LATERAL RUNOUT | 0.003 INCHES |
| OVERALL DIAMETER | 1.065 INCHES MAXIMUM |
| OVERALL LENGTH | 2.430 INCHES MAXIMUM |
| MAXIMUM STARTING TORQUE | 1.50 INCH-OUNCES |
| MOUNTING LIP DEPTH | 0.0570 INCHES MINIMUM AND 0.0670 INCHES MAXIMUM |
| MOUNTING LIP DIAMETER | 0.8700 INCHES MINIMUM AND 0.8800 INCHES MAXIMUM |
| MOUNTING METHOD | CLAMP RING(S) |
| PILOT DIAMETER | 0.7495 INCHES MINIMUM AND 0.7500 INCHES MAXIMUM |
| PILOT LENGTH | 0.0570 INCHES MINIMUM AND 0.0670 INCHES MAXIMUM |
| POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR 1ST SECTION AND 1.0 FREE AIR 2ND SECTION |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 1ST SECTION AND -10.0 TO 10.0 2ND SECTION |
| ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 3600.0 NOMINAL |
| SECTION QUANTITY | 2 |
| SHAFT END PLAY | 0.005 INCHES |
| SHAFT DIAMETER | 0.1245 INCHES MINIMUM AND 0.1247 INCHES MAXIMUM |
| SHAFT RADIAL PLAY | 0.002 INCHES |
| SHAFT RUNOUT | 0.001 INCHES |
| SHAFT STYLE | ROUND, SLOTTED |
| SHAFT LENGTH | 0.595 INCHES MINIMUM AND 0.655 INCHES MAXIMUM |
| UNDERCUT DIAMETER | 0.781 INCHES MAXIMUM |
| UNDERCUT WIDTH | 0.0570 INCHES MINIMUM |
| TEMP COEFFICIENT OF RESISTANCE WIRE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO 20.0 ALL SECTIONS |
| TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE LOCATION NOT OTHERWISE SPECIFIED |
| TERMINAL TYPE AND QUANTITY | 11 TURRET |
| TEST DATA DOCUMENT | 07217-629892 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |