| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| BODY LENGTH | 0.260 INCHES NOMINAL |
| INCLOSURE TYPE | ENCASED |
| MAXIMUM OPERATING TEMP | 175.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 10.00 MILLIWATTS |
| MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER | 0.164 INCHES |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING THREAD QUANTITY | 32 PER INCH |
| OVERALL DIAMETER | 0.250 INCHES NOMINAL |
| OVERALL LENGTH | 0.416 INCHES NOMINAL |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 3.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
| STYLE DESIGNATOR | SCREW MOUNTED |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LOOP |
| THERMAL TIME CONSTANT IN SECONDS | 10.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.85 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 214.0 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 22.07 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -3.0 TO 3.0 |
| ZERO POWER RESISTANCE | 1.000 KILOHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 39.00 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 50.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |