| EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 356.0 MINIMUM AND 357.0 MAXIMUM |
| ELECTRICAL RESISTANCE PER SECTION | 20.0 KILOHMS 1ST SECTION AND 20.0 KILOHMS 2ND SECTION AND 20.0 KILOHMS 3RD SECTION AND 100.0 KILOHMS 4TH SECTION |
| ACTUATOR TYPE | DOUBLE ENDED SHAFT |
| ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION |
| AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 55.0 ALL SECTIONS |
| AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 165.0 ALL SECTIONS |
| BEARING TYPE | BALL SHAFT |
| BODY DIAMETER | 3.000 INCHES NOMINAL |
| BODY LENGTH | 4.781 INCHES MAXIMUM |
| BODY STYLE | CYLINDRICAL SERVO MOUNTED |
| FEATURES PROVIDED | SWITCH |
| FIXED TAP QUANTITY PER SECTION | 32 ALL SECTIONS |
| FUNCTION CHARACTERISTIC PER SECTION | ALL SECTIONS LINEAR |
| FUNCTION CONFORMITY PER SECTION | ALL SECTIONS INDEPENDENT LINEARITY |
| FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.25 TO 0.25 ALL SECTIONS |
| LATERAL RUNOUT | 0.003 INCHES |
| MAXIMUM RUNNING TORQUE | 3.50 INCH-OUNCES |
| MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
| MOUNTING LIP DEPTH | 0.09300 INCHES NOMINAL |
| MOUNTING LIP DIAMETER | 3.00000 INCHES NOMINAL |
| MOUNTING METHOD | CLAMP RING(S) |
| PILOT DIAMETER RUNOUT | 0.00150 INCHES |
| PILOT DIAMETER | 2.87500 INCHES NOMINAL |
| PILOT LENGTH | 0.06200 INCHES NOMINAL |
| POWER DISSIPATION RATING PER SECTION IN WATTS | 5.0 FREE AIR ALL SECTIONS |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 ALL SECTIONS |
| ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
| SECTION QUANTITY | 4 |
| SHAFT END PLAY | 0.00100 INCHES |
| SHAFT DIAMETER | 0.2498 INCHES NOMINAL |
| SHAFT RADIAL PLAY | 0.001 INCHES |
| SHAFT RUNOUT | 0.001 INCHES |
| SHAFT STYLE | ROUND |
| SHAFT LENGTH | 0.875 INCHES NOMINAL |
| SWITCH TYPE | ROTARY |
| SWITCH VOLTAGE RATING IN VOLTS | 50.0 |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW, THREE POSITIONS MAINTAINED |
| SWITCH CURRENT TYPE AND RATING IN AMPS | 0.100 DC |
| SWITCH OPERATING POSITION | START OF ROTATION |
| TAP LOCATION TOLERANCE PER SECTION | -0.25 TO 0.25 DEG ANGULAR ROTATION ALL SECTIONS |
| TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 ALL SECTIONS |
| TERMINAL LOCATION | RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE LOCATION NOT OTHERWISE SPECIFIED |
| TERMINAL TYPE AND QUANTITY | 143 TURRET |
| TEST DATA DOCUMENT | 18876-10243506 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| UNDERCUT DIAMETER | 2.875 INCHES NOMINAL |
| UNDERCUT WIDTH | 0.07300 INCHES MINIMUM |