| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.0624 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.6874 INCHES NOMINAL |
| CUBIC MEASURE | 0.342 CUBIC INCHES |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL |
| INCLOSURE TYPE | ENCAPSULATED |
| OVERALL HEIGHT | 0.313 INCHES NOMINAL |
| OVERALL LENGTH | 1.250 INCHES NOMINAL |
| OVERALL WIDTH | 0.875 INCHES NOMINAL |
| MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 150.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 NINTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -11.0 TO 11.0 FIRST RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.1 TO 12.1 TENTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 FIFTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0 TO 7.0 SIXTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0 TO 7.0 FOURTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.4 TO 8.4 THIRD RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.6 TO 8.6 SEVENTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 SECOND RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.9 TO 8.9 EIGHTH RESISTANCE-TEMPERATURE POINT |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.1285 INCHES NOMINAL |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 116.0 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 13.05 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 13.05 OHMS TENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.465 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 58.0 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 725.0 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| ZERO POWER RESISTANCE | 725.000 OHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 4.40 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 239.25 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 25.375 OHMS NINTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.045 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 46.4 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | DISK ON SURFACE PLATE |
| SURFACE TREATMENT | SOLDER TERMINAL |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -10.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -30.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 25.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| TERMINAL LENGTH | 3.750 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 1 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 80.0 |