| ELECTRICAL RESISTANCE | 3.010 KILOHMS |
| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
| BODY DIAMETER | 0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM |
| BODY LENGTH | 1.718 INCHES MINIMUM AND 1.842 INCHES MAXIMUM |
| CUBIC MEASURE | 0.238 CUBIC INCHES |
| INCLOSURE TYPE | ENCAPSULATED |
| POWER DISSIPATION RATING IN WATTS | 10.000 FREE AIR |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-26/5 GOVERNMENT SPECIFICATION |
| STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -30.0 TO 30.0 |
| TERMINAL LENGTH | 1.375 INCHES MINIMUM AND 2.125 INCHES MAXIMUM |
| TERMINAL TYPE | WIRE LEAD |
| TEST DATA DOCUMENT | 81349-MIL-R-26 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |