4010-00-075-5195 LINK,CHAIN,END Index 5325-00-075-5197 INSERT,SCREW THREAD

National Stock Number:
5905-00-075-5196

Federal Supply Class:
5905

National Item Identification Number:
000755196

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
5800332-9749-002C0426HENSOLDT SENSORS GMBH
TM1/8 102K01295TEXAS INSTRUMENTS INCORPORATED


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY LENGTH0.406 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.140 INCHES NOMINAL
CUBIC MEASURE0.005 CUBIC INCHES
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP125.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING0.125 WATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS25.0
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP2.0 KILOHMS NINTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP2.23 KILOHMS TENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE1.000 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS0.70
STYLE DESIGNATORROD
SURFACE TREATMENTSOLDER TERMINAL
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-25.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-65.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-75.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER125.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER75.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS60.0