| AMBIENT TEMP AT FULL RATED POWER | 50.0 CELSIUS |
| BODY OUTSIDE DIAMETER | 0.850 INCHES NOMINAL |
| BODY WIDTH | 0.250 INCHES NOMINAL |
| INCLOSURE TYPE | UNINCLOSED |
| MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 1.50 WATTS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 15.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.0 TO 13.0 ALL RESISTANCE-TEMPERATURE POINTS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 28.3 OHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 10.000 OHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -6.95 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.1 OHMS SECOND RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | DISK |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.030 INCHES NOMINAL |
| TERMINAL LENGTH | 3.750 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 450.0 |