| AMBIENT TEMP AT FULL RATED POWER | 100.0 CELSIUS |
| BODY LENGTH | 0.390 INCHES MINIMUM AND 0.420 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM |
| INCLOSURE TYPE | ENCAPSULATED |
| MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| MAXIMUM POWER DISSIPATION RATING | 125.00 MILLIWATTS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.5 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.3 TO 5.3 FIFTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -6.6 TO 6.6 SIXTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -6.7 TO 6.7 FOURTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.4 TO 7.4 THIRD RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.2 TO 7.2 SEVENTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.3 TO 8.3 FIRST RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.5 TO 8.5 EIGHTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.0 TO 8.0 SECOND RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.2 TO 9.2 NINTH RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | ROD |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -65.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -75.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| TERMINAL LENGTH | 1.000 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 35.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 10.48 KILOHMS TENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 9.4 KILOHMS NINTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| ZERO POWER RESISTANCE | 4.700 KILOHMS |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |