| ADJUSTMENT DEVICE TYPE AND QUANTITY | 1 KNOB |
| APPLICATION DESIGN | WAVEGUIDE |
| ATTENUATION ACCURACY REFERENCE FREQUENCY | 6.6 GIGAHERTZ |
| ATTENUATION VARIATION METHOD | CONTINUOUS |
| BODY STYLE | WAVEGUIDE TYPE |
| FREQUENCY RANGE | 5.850 GIGAHERTZ MINIMUM AND 8.200 GIGAHERTZ MAXIMUM |
| OPERATING TEMP RANGE | -40.0 TO 55.0 CELSIUS |
| OVERALL ATTENUATION ACCURACY IN DECIBELS | -1.50 TO 1.50 |
| OVERALL ATTENUATION RANGE IN DECIBELS | +0.0 TO 20.0 |
| OVERALL HEIGHT | 5.281 INCHES NOMINAL |
| OVERALL LENGTH | 5.600 INCHES NOMINAL |
| OVERALL WIDTH | 3.125 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
| POWER RATING | 3.0 WATTS AVERAGE |
| SCALE DIVISION QUANTITY | 20 |
| SCALE LINEARITY | NONLINEAR |
| VOLTAGE STANDING WAVE RATIO | 1.15 |
| WAVEGUIDE FLANGE DESIGNATION | UG-344/U |
| WAVEGUIDE FLANGE TYPE | COVER |
| TERMINAL TYPE AND QUANTITY | 2 FLANGE |