| MEASURING METHOD AND LENGTH | 4.000 FEET MINIMUM RANDOM |
| MOISTURE CONTENT RETENTION PERCENTAGE | 15.0 MAXIMUM |
| NONDEFINITIVE SPEC/STD DATA | 2 TABLE |
| PRESERVATIVE SOLUTION TYPE | ACID COPPER CHROMATE OR AMMONIACAL COPPER ARSENITE OR CHROMATED COPPER ARSENATE, TYPE I, II OR III OR PENTACHLOROPHENOL IN VOLATILE SOLVENT |
| RANDOM LENGTH | 4 FT AND LONGER,WITH A MAX OF 5 PCT TO BE 4-7 FT AND A MIN OF 50 PCT TO BE 12 FT AND LONGER |
| SERVICE USAGE | LUMBER OR FOR USE ABOVE GROUND |
| SPECIES-GRADE AND GRADING ASSOCIATION | ANY ACCEPTABLE C SELECT NORTHEASTERN LUMBER MANUFACTURERS ASSOCIATION OR ANY ACCEPTABLE C SELECT NORTHERN HARDWOOD AND PINE MANUFACTURERS ASSOCIATION OR ANY ACCEPTABLE C AND BETTER SIDING WEST COAST LUMBER INSPECTION BUREAU OR ANY ACCEPTABLE C SELECT WESTERN WOOD PRODUCTS ASSOCIATION OR PINE, IDAHO WHITE CHOICE WESTERN WOOD PRODUCTS ASSOCIATION OR PINE, SOUTHERN C DROP SIDING SOUTHERN PINE INSPECTION BUREAU OR REDWOOD CLEAR REDWOOD INSPECTION SERVICE |
| SPECIFICATION/STANDARD DATA | 81348-MM-L-751 GOVERNMENT SPECIFICATION |
| WIDTH-LOCATION AND MEASURING METHOD | 6.000 INCHES NOMINAL OVERALL SPECIFIED |
| SUPPLEMENTARY FEATURES | SEE TT-W-571,TABLE 1,FOR ACCEPTABLE SPECIES,TONGUED AND GROOVED,UNIT OF ISSUE BF |
| SURFACE CONDITION DEGREE | DROP SIDING PATTERN 105 FULL LENGTH |
| THICKNESS-LOCATION AND MEASURING METHOD | 1.000 INCHES NOMINAL OVERALL SPECIFIED |
| TREATMENT TYPE | PRESERVATIVE, TT-W-571 |
| TYPICAL WOOD PRODUCTS USE | PRESERVATIVE TREATED HIGH QUALITY DROP SIDING |