CENTER INSIDE CLEARANCE HEIGHT | 45.000 FEET MINIMUM |
DOOR LOCATION | END WALL FIRST DOOR |
DOOR LOCATION | END WALL SECOND DOOR |
DOOR LOCATION | END WALL THIRD DOOR |
DOOR OPENING HEIGHT | 7.000 FEET NOMINAL FIRST DOOR |
DOOR OPENING LOCATION | END WALL FIRST DOOR |
DOOR OPENING LOCATION | END WALL SECOND DOOR |
DOOR OPENING LOCATION | END WALL THIRD DOOR |
DOOR OPENING HEIGHT | 16.000 FEET NOMINAL SECOND DOOR |
DOOR OPENING HEIGHT | 30.000 FEET NOMINAL THIRD DOOR |
DOOR OPENING TYPE | UNFRAMED THIRD DOOR |
DOOR OPENING WIDTH | 16.000 FEET NOMINAL SECOND DOOR |
DOOR OPENING WIDTH | 160.000 FEET NOMINAL THIRD DOOR |
DOOR OPENING QUANTITY | 4 |
DOOR OPENING TYPE | FRAME FIRST DOOR |
DOOR OPENING TYPE | UNFRAMED SECOND DOOR |
DOOR OPENING WIDTH | 3.000 FEET NOMINAL FIRST DOOR |
DOOR TYPE AND QUANTITY | 2 HINGED SINGLE FIRST DOOR |
DOOR TYPE AND QUANTITY | 2 HORIZONTAL SLIDING SECTIONAL THIRD DOOR |
DOOR TYPE AND QUANTITY | 2 HORIZONTAL SLIDING SINGLE SECOND DOOR |
INSULATION LOCATION | UNINSULATED |
MATERIAL | CONCRETE FLOOR |
NOMINAL LENGTH | 110.000 FEET |
NOMINAL WIDTH | 160.000 FEET |
ROOM QUANTITY | 1 |
SHUTTER QUANTITY | 5 |
SIDEWALL INSIDE CLEARANCE HEIGHT | 30.000 FEET MINIMUM |
SPECIAL FEATURES | FURNISHED W/ONE SINGLE HINGED-TYPE DOOR LOCATED IN SLIDING SECTIONAL DOOR,EQUIPPED W/TWO STEAM HEATERS W/ELEC MOTOR DRIVEN,HANGAR IS EXPANDABLE TO A MILTIPLE HANGAR ARRANGEMENT ON EITHER SIDE OF HANGAR,EXPLOSION-PROOF ELEC POWER WIRING SYSTEM,ERECTION HAND TOOLS,AKGF AND AKGG MIN.;FLOOR MATERIAL CONCRETE,PARTIALLY PANELLED FEATURE NOT INCLUDED |
SPECIFICATION/STANDARD DATA | 81349-MIL-B-28543 GOVERNMENT SPECIFICATION |
STYLE DESIGNATOR | RIGID FRAME GABLE |
VENTILATOR OPENING QUANTITY | 5 |