| DISTANCE BETWEEN MOUNTING HOLE CENTERS | 2.000 INCHES NOMINAL |
| DISTANCE FROM FLANGE TO END | 0.447 INCHES NOMINAL |
| FLANGE LENGTH | 2.500 INCHES NOMINAL |
| FLANGE MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
| FLANGE THICKNESS | 0.103 INCHES MINIMUM AND 0.123 INCHES MAXIMUM |
| FLANGE WIDTH | 2.500 INCHES NOMINAL |
| HEIGHT | 2.067 INCHES MINIMUM AND 2.097 INCHES MAXIMUM |
| INSIDE DIAMETER | 0.250 INCHES MINIMUM AND 0.252 INCHES MAXIMUM |
| LOAD/FREQUENCY RANGE | 21 LB STATIC RADIAL LOAD AND 60 LB STATIC AXIAL LOAD FOR 32 HERTZ IN RADIAL DIRECTION |
| MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE WASHER |
| MATERIAL | STEEL CORROSION RESISTING INNER MEMBER |
| MATERIAL | STEEL CORROSION RESISTING OUTER RING |
| MATERIAL | STEEL HOUSING |
| SHORTEST DISTANCE BETWEEN MOUNTING HOLE CENTERS | 2.000 INCHES NOMINAL |
| STYLE DESIGNATOR | ROUND FOUR-HOLE FLANGE |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-P-416, TYPE 2, CLASS 1 FED SPEC SINGLE TREATMENT RESPONSE HOUSING |
| SURFACE TREATMENT | CADMIUM HOUSING |
| SURFACE TREATMENT | PASSIVATE INNER MEMBER |
| SURFACE TREATMENT | PASSIVATE OUTER RING |