| COUNTERSINK ANGLE | 99.0 DEGREES MINIMUM AND 101.0 DEGREES MAXIMUM |
| FASTENER LENGTH | 0.758 INCHES MINIMUM AND 0.768 INCHES MAXIMUM |
| GRIP LENGTH | 0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM |
| HEAD HEIGHT | 0.043 INCHES MINIMUM AND 0.054 INCHES MAXIMUM |
| HEAD STYLE | CROWN COUNTERSUNK LESS THAN 135 DEGREES |
| HEAD MAJOR DIAMETER | 0.2930 INCHES MINIMUM AND 0.3047 INCHES MAXIMUM |
| MATERIAL DOCUMENT AND CLASSIFICATION | AMS 5629 NATIONAL STD/SPEC SINGLE MATERIAL RESPONSE OVERALL |
| MATERIAL | STEEL COMP XM-13 OVERALL |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | PIN-RIVET,GROOVED,100 DEGREE COUNTERSUNK HEAD,SHEAR,LOCKBOLT,STUMP TYPE,CRES,125 KSI FSU |
| SHANK DIAMETER | 0.1890 INCHES MINIMUM AND 0.1895 INCHES MAXIMUM |
| SHANK STYLE | STUMP |
| SHEAR STRENGTH | 125000 SINGLE POUNDS PER SQUARE INCH |
| SPECIFICATION/STANDARD DATA | 76301-3-1261 MANUFACTURERS STANDARD |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | AMS2700,METHOD 1 OR 2 NATIONAL STD/SPEC SINGLE TREATMENT RESPONSE OVERALL |
| SURFACE TREATMENT | PASSIVATE OVERALL |