| DOOR | PROVIDED |
| ASSEMBLY FORM | ASSEMBLED |
| CLOSURE METHOD | HINGED COVER |
| CIRCULATION METHOD | MECHANICAL |
| COMPARTMENT QUANTITY | 1 |
| COOLING COILS FOR BELOW ROOM TEMP USE | INCLUDED |
| CONTROL TYPE | TOGGLE SWITCH AND SELECTOR SWITCH AND BLEEDER VALVE AND VACUUM GAGE |
| CUBIC MEASURE | 172800.000 CUBIC INCHES |
| CURRENT TYPE | AC |
| ENVIRONMENTAL CHAMBER TYPE | TEMPERATURE |
| FREQUENCY RATING | 55.0 HERTZ MINIMUM AND 65.0 HERTZ MAXIMUM |
| HEATING METHOD | ELECTRICAL |
| HEAT SOURCE FOR WHICH DESIGNED | INTEGRAL |
| INSIDE DEPTH | 26.000 INCHES NOMINAL |
| INSIDE HEIGHT | 30.000 INCHES NOMINAL |
| INSIDE WIDTH | 28.000 INCHES NOMINAL |
| OVERALL WIDTH | 48.000 INCHES NOMINAL |
| MATERIAL | COPPER AND RUBBER CHLOROPRENE CLASS CR LOCATION NOT OTHERWISE SPECIFIED |
| OPENING LOCATION | LEFT SIDE OR RIGHT SIDE |
| OPERATING TEMP RANGE | -73.3 TO 121.0 CELSIUS |
| OUTER DOOR QUANTITY | 2 |
| OVERALL DEPTH | 48.000 INCHES NOMINAL |
| OVERALL HEIGHT | 75.000 INCHES NOMINAL |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | TEMPERATURE CHAMBER |
| PHASE | THREE |
| POWER RATING | 350.0 WATTS MINIMUM AND 1000.0 WATTS MAXIMUM |
| SPECIAL FEATURES | TEMPERATURE CHAMBER WITH REMOVABLE HOLDING RACK 1 NEOPRENE PLUG 4.000 IN. DIA. PRESSURE CONTROL PANEL, RUBBER TUBING EA 8.000FT LG., 3 PLUGS |
| SUPPLEMENTARY FEATURES | THE CHAMBER IS USED FOR SUBJECTING ALTIMETERS AND ALTITUDE TRANSDUCER COMPUTERS, SIMILAR TO THE AAU-19/A AND CPU-46/A RESPECTIVELY, TO PRECISELY CONTROLLED TEMPERATURE ENVIRONMENTS DURING SCALE ERROR TESTING |
| SURFACE TREATMENT | ZINC AND ENAMEL |
| VOLTAGE RATING | 220.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |